Gluing Control Systems
Home > List of Products > Gluing Control Systems > Paper Checker PC300G / PC110A
Gluing Control Systems
Related Equipment
Paper Checker PC300G / PC110A
Overview |  Feature |  Specifications | 

Paper Checker  PC300G / PC110A

Overview

These paper checkers can be used in a wide range of web-handling processes to inspect splices and breaks in the web.

PC300G
This is a double-sheet feed detector for box-making machines. Besides paper, it can also be used with aluminum laminated paper, poly-laminated paper, plastics and a range of other materials. It can also handle a wide range of thickness, and the thickness in use can be selected from a switch on the operation panel for changeovers. The PC300G can detect double sheets that may occur due to the material or to operator error, and immediately prevents them from being fed in.

PC110A
This checker monitors the number of overlapping sheets in a web, and can output a contact signal if the number of overlapping sheets increases or decreases. Perfect for use in detecting folding errors and missing folds in fold collators. The automatic zero-adjustment function means that you don't have to adjust the zero when the paper changes. The detection result is displayed as a plus (+) or minus (-) in relation to the standard number of layers in the web being monitored.

PC300G features
Non-contact detection. Printed text and images will not cause errors.

PC110A features
Automatic zero-adjustment function. Non-contact detection. Colors and printing will not cause errors. Can detect a variation of ±1 sheet in approx. 10 sheets. The display makes it easy for the operator to make decisions.

PC300G
Detecting method Non-contact transmission
Applications Double-sheet detector for box-making machines
Materials that can be checked Paper, aluminum laminate, poly-laminate, plastics Material thickness: 0.04 to 1.0 mm (for paper)
Input Interlocked signal, output reset signal
Operating speed 100 m/min. (overlap of 20 mm)
300 m/min. (overlap of 60 mm)
Power supply 100 to 240 V AC, 50/60 Hz
Power consumption 10 VA (max)
Ambient operating temp. 0~50℃
Mass Controller 2 kg, sensor 0.4 kg (one set, including cables)
External dimensions Controller: 254 (W) x 70 (H) x 170 (D) mm
Detector:Ͷ 30 x 35.5
PC110A
Detecting method Non-contact transmission
Applications Detection of folding errors and missing folds in collators
No. of sheets monitored Up to 10
Input Synchronous signal, output reset signal 15 V DC, 3 mA Dry contact or open collector
Output Contact output Dry contact: max. rating 240 V AC, 0.1 A or 24 V DC, 0.1 A
Operating speed 200 m/min. (max) (with a web fold length of 15 cm)
Power supply 100 to 240 V AC (automatic voltage selection), 50/60 Hz
Power consumption 5 VA (max)
Ambient operating temp. 0~40℃
Mass Controller 2 kg, sensor 0.9 kg ( including cables)
External dimensions Controller: 280 (W) x 70 (H) x 171 (D) mm
Detector: 233 (W) x 70 (H) x 40 (D) mm