					Overview
The PILOTJET is an industrial servo valve for converting electric signals (-200 to +200 mA DC) Please confirm with client. Into hydraulic signals, which is used mainly for EPC® in steel plants. The PILOTJET uses a highly reliable jet pipe system that has been extensively used, to ensure high operability and easy maintenance.
Feature
- A dry detecting unit, that is not affected by magnetic dust in oil, reduces periodic maintenance.
- A jet pipe system with extensive experience of use provides hydraulic control.
- A servo mechanism for handing low to high flowrates is available in combination with a variety of gain boosters.
- A wide range of gain boosters is available with hydraulic pressures of 0.8 to 14 MPa.
- A simple structure allows for disassembly, reassembly, and adjustment in your plant.
- Easy operation and maintenance
Specifications
Single PILOTJET Controller
| Input signal: | +200 – 0 – -200mA DC (zero balance) | 
|---|---|
| Resistance of moving coil: | About 20Ω | 
| Supply oil pressure: | 1.2MPa | 
| Jet pipe capacity*: | About 3.5ℓ/min (at 1.2MPa) | 
| Hysteresis error: | Less than 2% | 
| Fluctuation of neutral point: | Less than 2% | 
Manifold Controller
| Model of manifold controller | M4SJ240 | M5SJ240 | M6SJ240 | 
|---|---|---|---|
| Gain booster | BO9M | BO9HM | BO10M | 
| Maximum hydraulic pressure MPa | 5 | 14 | 10 | 
| Mass kg | About 23 | About 28 | About 48 | 
| Hydraulic pressure of jet pipe MPa | 1.2 | ||
| Permissible back pressure of return oil MPa | 0.1 | ||