Edge Position Control Systems
- High Functionality EPC/CPC Amplifier SGA3100
- Inductive Autowide Sensors AWI Series
- PHOTOHEAD PH50, PH51
- Linear Sensor LSF4096
- Analog Position Transmitter FW80
- Modular Strip Guide system controller MGC1000
- Electromagnetic CPC Sensor Model:EMW
- Capacitance Autowide AWC Series
- Electromagnetic Guidance NS-CPC Sensor
- AUTOWIDE™AWL
- PHOTOHEAD PH30, PH31
- Strip Guide Amplifier SGA3000
- PILOTJET
- Power Guide PG300, 500, 800
- Analog Position Transmitter FW22, FW31
- High-precision Position Transmitter GYKM-LT
-
Measuring Systems
-
Actuators
-
Movie
Power Guide PG300, 500, 800
Overview
The Power Guide servo valve is back, lighter, and with even stronger erformance than ever before. Compatible with older models through a specialized adapter, and as easy to use as ever, Power Guide servo valves combine high performance and convenience with the toughness to work in dirty environments, changing the face of industrial servo valves.
Feature
-
Compact
Smaller and lighter, the unit has only one fifth the volume of previous models.
-
High responsivity>
45Hz/-3dB
Power Guide servo valves feature high responsivity and high gain, with low hysteresis, achieving high levels of precision in EPC and CPC. -
Maintenance
The structure uses a double pilot format proven over extended use. The simple servo valve structure is even usable with general hydraulic oil*.
*: Hydraulic oil of NAS11 grade may be used, but there may be problems with NAS11 or lower if there is a high concentration of debris of 5μ or smaller.
Specifications
Model | PG300 | PG500 | PG800 |
---|---|---|---|
Dimensions | 114 x 224 x 70 | ||
Rated pressure | 2 – 14MPa | ||
Rated flow L/min | 25 | 50 | 80 |
Return-side pressure resistance | Internal drain: 1MPa External drain3: MPa |
||
Internal leakage L/min | 3 | 3.5 | 4.5 |
Response of frequency | 45Hz (-3dB) | ||
Hysteresis | 1% | ||
Ambient operating temperature | 0 – 50°C | ||
Hydraulic oil temperature | 10 – 60°C 《10 – 50°C》 | ||
Hydraulic oil viscosity range | 20 – 80 mm/S (cSt) | ||
Hydraulic oil contamination grade | NAS grade 11/Mass grade 103 | ||
Line filter | 10μm(β10≧200) | ||
Moving Coil resistance value | 18.5Ω 《20》 | ||
Rated current | ±200mA DC | ||
Recommended dither signal (100Hz) | 2Vp-p | ||
Fixed orifice | φ0.4mm 《φ0.45mm》 | ||
Hydraulic oil | Mineral oil (water glycol under development) Fatty acid ester, mineral oil, phosphate ester and water-glycol types |
Contact Us